NetRack
A rack is the frame that every other piece of equipment depends on, and getting it right saves trouble for years. MetaPoint Technologies supplies Netrack floor-standing server racks, currently a 36U and a 42U model, to server rooms, branch offices and data centres across Hyderabad, Telangana, Andhra Pradesh and Karnataka, and can install the equipment inside them.
About Netrack
Netrack is an Indian manufacturer of racks, enclosures and cabinets for IT and telecom equipment. A 19-inch rack standardises the mounting width for servers, switches, patch panels, storage and power distribution units, and its height is counted in rack units (U), where one U is 44.45 mm. Netrack server racks are fabricated from steel and typically include vented front and rear doors, side panels, adjustable mounting rails, cable entry points and provision for fans and power strips. The airflow design matters: servers and switches pull cool air from the front and push hot air out of the back, so a perforated door and sensible blanking of empty slots keep temperatures predictable. A rack is also a security boundary, because lockable doors and side panels limit who can touch the equipment.
Netrack products available from MetaPoint Technologies
MetaPoint Technologies lists two Netrack server racks:
- Netrack 36U 8 x 10 server rack, a mid-height cabinet suited to server rooms with limited ceiling height or to a smaller stack of switches, storage and a few servers.
- Netrack 42U 8 x 10 server rack, the standard full-height data centre cabinet, with more room for servers, patch panels and power distribution.
The 8 x 10 designation in the product names refers to the rack footprint, so confirm the width and depth you need for deeper servers when you request a quote. For other rack styles, such as wall-mount cabinets and open racks, see our racks category, server racks and network racks. Netrack accessories such as shelves, fan trays and power strips can be quoted with the cabinet. See the Netrack brand page.
Who Netrack is right for
A 42U cabinet suits a server room that will host several rack servers, a storage array, core switches and a patch panel, and it gives space to grow. The 36U model suits smaller server rooms, offices with lower ceilings, or a network and storage rack that will not be filled completely. Colleges, hospitals, factories and mid-size companies commonly start with one rack and add a second as they virtualise. If you only need to house a switch and a small firewall in a branch, a wall-mount cabinet may be a better and cheaper choice, and we will say so.
How to choose the right Netrack solution
List what the rack must hold today and in three years, then add twenty to thirty per cent for growth. Check the depth of your deepest server, since some rack servers need more than a standard cabinet offers once cables are included. Plan weight: a fully loaded rack can be heavy, so check the floor and how it will be moved into the room. Think about power and cooling before the rack arrives, with enough PDU outlets and airflow clearance at the front and back. Decide how cables will enter the cabinet, from the top, bottom or both, and leave space for vertical cable managers. Finally, work out whether you need a lock, extra fans, a shelf for non-rackable devices or an earthing kit. Our guide to data centre setup costs in Hyderabad covers the surrounding power and cooling considerations.
From empty rack to working server room
MetaPoint Technologies can place the rack, mount servers and switches, route and label cabling with CommScope or Molex patch panels and cords, and document the layout. Our data centre solutions page explains how we plan power, cooling and cabling together.
Deployment and support from MetaPoint Technologies
MetaPoint Technologies can supply Netrack products alone or deliver a complete structured-cabling project: survey, installation, cable management, labelling, certification testing and as-built documentation, including server room and MDF/IDF cabinet work.
Planning your Netrack purchase
Before a Netrack installation, share floor plans or the number of points required, cable categories and lengths, rack and cabinet locations, and the schedule. We will survey, quote a complete bill of materials and plan the work around your operations.
Why buy Netrack from MetaPoint Technologies
MetaPoint Technologies has delivered projects for 100+ businesses across South India and works with 36 vendor partners. You get genuine products, manufacturer warranty, help with claims, and engineers who have deployed these platforms in real environments.
Related reading and pages
Data Centre Setup in Hyderabad: 2026 Cost & Equipment Guide; What devices are required to set up a data centre; Server racks; Network racks; Racks category.
Request a quote. For other rack styles, such as wall-mount cabinets and open racks, see our racks category, server racks and network racks. Netrack accessories such as shelves, fan trays and power strips can be quoted with the cabinet. See the Netrack brand page.
Who Netrack is right for
A 42U cabinet suits a server room that will host several rack servers, a storage array, core switches and a patch panel, and it gives space to grow. The 36U model suits smaller server rooms, offices with lower ceilings, or a network and storage rack that will not be filled completely. Colleges, hospitals, factories and mid-size companies commonly start with one rack and add a second as they virtualise. If you only need to house a switch and a small firewall in a branch, a wall-mount cabinet may be a better and cheaper choice, and we will say so.
How to choose the right Netrack solution
List what the rack must hold today and in three years, then add twenty to thirty per cent for growth. Check the depth of your deepest server, since some rack servers need more than a standard cabinet offers once cables are included. Plan weight: a fully loaded rack can be heavy, so check the floor and how it will be moved into the room. Think about power and cooling before the rack arrives, with enough PDU outlets and airflow clearance at the front and back. Decide how cables will enter the cabinet, from the top, bottom or both, and leave space for vertical cable managers. Finally, work out whether you need a lock, extra fans, a shelf for non-rackable devices or an earthing kit. Our guide to data centre setup costs in Hyderabad covers the surrounding power and cooling considerations.
From empty rack to working server room
MetaPoint Technologies can place the rack, mount servers and switches, route and label cabling with CommScope or Molex patch panels and cords, and document the layout. Our data centre solutions page explains how we plan power, cooling and cabling together.
Deployment and support from MetaPoint Technologies
MetaPoint Technologies can supply Netrack products alone or deliver a complete structured-cabling project: survey, installation, cable management, labelling, certification testing and as-built documentation, including server room and MDF/IDF cabinet work.
Planning your Netrack purchase
Before a Netrack installation, share floor plans or the number of points required, cable categories and lengths, rack and cabinet locations, and the schedule. We will survey, quote a complete bill of materials and plan the work around your operations.
Why buy Netrack from MetaPoint Technologies
MetaPoint Technologies has delivered projects for 100+ businesses across South India and works with 36 vendor partners. You get genuine products, manufacturer warranty, help with claims, and engineers who have deployed these platforms in real environments.
Related reading and pages
Data Centre Setup in Hyderabad: 2026 Cost & Equipment Guide; What devices are required to set up a data centre; Server racks; Network racks; Racks category.
Frequently asked questions
What does 42U mean?
U is a rack unit, equal to 44.45 mm of mounting height. A 42U rack provides 42 of those units for servers, switches and panels.
Which Netrack model should I choose, 36U or 42U?
Choose 42U for a full data room with room to grow, and 36U where ceiling height or the equipment count is smaller.
Can you install equipment in the rack?
Yes. We mount servers, switches and patch panels, route and label cables, and document the layout.
Do I need cooling for a server rack?
Yes. Plan airflow and room temperature before the rack arrives, and keep empty slots blanked so hot and cold air do not mix.
Request a quote
Request a Netrack quote. Tell us the model or use case and we will respond with pricing and options. Contact us on +91 99895 44438 or satish@metapoint.in, or via the contact page.
Frequently Asked Questions
What NetRack products does MetaPoint Technologies supply?
MetaPoint Technologies supplies server and network racks, helping businesses across Hyderabad, Telangana, Andhra Pradesh, and Karnataka with housing and organising IT equipment.
Is MetaPoint Technologies an authorised NetRack partner in South India?
Yes. MetaPoint Technologies is an authorised NetRack partner, supplying, installing, and supporting NetRack products for enterprise and SMB clients across Hyderabad, Telangana, Andhra Pradesh, and Karnataka.
Does MetaPoint Technologies provide installation for NetRack cabling and connectivity products?
Yes. MetaPoint Technologies's technicians handle installation, termination, and testing of NetRack products as part of structured cabling projects across Hyderabad, Telangana, Andhra Pradesh, and Karnataka.
How do I get a quote for NetRack products from MetaPoint Technologies?
MetaPoint Technologies, with 15 years of IT infrastructure experience, provides a tailored quote for NetRack products based on your requirement. Contact MetaPoint Technologies's pre-sales team serving Hyderabad, Telangana, Andhra Pradesh, and Karnataka to get started.
What does 42U mean?
U is a rack unit, equal to 44.45 mm of mounting height. A 42U rack provides 42 of those units for servers, switches and panels.
Which Netrack model should I choose, 36U or 42U?
Choose 42U for a full data room with room to grow, and 36U where ceiling height or the equipment count is smaller.
Can you install equipment in the rack?
Yes. We mount servers, switches and patch panels, route and label cables, and document the layout.
Do I need cooling for a server rack?
Yes. Plan airflow and room temperature before the rack arrives, and keep empty slots blanked so hot and cold air do not mix.